⎝⎛188比分直播⎞⎠

您好,欢迎来到深圳市威悍防静电科技有限公司官方网站! Favorite Weihan | Feedback | Hello, Welcome to the official website of Shenzhen Weihan Antistatic Technology Co., Ltd.!

common problem

FAQ

Using an ion fan to clean the substrate sounds simple and obvious, but how do you use an ion fan to clean the substrate ..
The fabric of anti-static clothing is generally a synthetic fiber fabric embedded with conductive wire, although the fiber itself is difficult to be cleaned ..
The industry stipulates that the safety voltage is 36V and the safety current is 10mA. The degree of harm to the human body from electric shock depends mainly on passing people

contact details

FAQ

Shenzhen Weihan Antistatic Technology Co., Ltd.

Contact: Miss Yang

Phone: 86-0755-29981716

Mobile: 13580960057

Fax: 86-0755-29981710

Address: No.53, Xisan Street, Fuxin District, Qiaotou Community, Houjie Town, Dongguan City

人体静电消除器 Your current location : ⎝⎛188比分直播⎞⎠ - Products - Static Eliminator Series - Human Body Static Eliminator

Product name: Sound and light alarm human body electrostatic discharge ball

Product model: WH-7900D

Product features: WH-7900D human body electrostatic discharge alarm is an instrument for human body static discharge in flammable, explosive and antistatic places.

product details

WH-7900D Human Body Electrostatic Discharge Alarm is an instrument that is suitable for human body electrostatic discharge in flammable, explosive and anti-static places. Its characteristic lies in the design of reasonable human body electrostatic discharge resistance, reasonable and effective control of electrostatic discharge, prolonging the human body electrostatic discharge time, reducing the instant human body electrostatic discharge energy, and enabling the human body to discharge static electricity safely. At the same time, it can detect whether the contact between the human body and the electrostatic touch ball is reliable, and the audible and visual alarm prompts whether the static elimination is complete.
The design of WH-7900D human body electrostatic discharge alarm refers to the following national standards:
GB12158-2006 "General Guidelines for Preventing Static Electricity Accidents"
GB5074-2002 "Code for Design of Petroleum Depots"
Article 14.3.13 stipulates that: as people wear artificial fabric clothes, artificial fabrics are extremely prone to static electricity. They tend to accumulate on the human body. In order to prevent the sparks that may be generated by static electricity, it is necessary to install a device to remove human static electricity on the escalator or the entrance to the oil pump room, the top of the light oil tank, the operating platform in the light oil work area, and the explosion danger area. This anti-static device refers to a handrail made of a metal tube. Before entering these places, the human body should touch the handrail to eliminate static electricity from the human body.
SH3097-2000 "Code for Design of Electrostatic Buildings in Petrochemical Industry"
The human body electrostatic discharge alarm passed the National Explosion-proof Electrical Product Quality Supervision and Inspection Center {NCEX}, and meets the following standards: GB3836.1-2010 Explosive environment Part 1: General requirements for equipment
GB3836.4-2010 Explosive environment Part 4: Equipment protected by intrinsically safe "I"
The product explosion-proof mark is ExiallCT4Gc.
  • Related Products
  • Repair and maintenance
  • Installation and operation
  • after-sale warranty
  • about transportation
  • regarding payment
WH-7900D Human Body Electrostatic Discharge Alarm is an instrument that is suitable for human body electrostatic discharge in flammable, explosive and anti-static places. Its characteristic lies in the design of reasonable human body electrostatic discharge resistance, reasonable and effective control of electrostatic discharge, prolonging the human body electrostatic discharge time, reducing the instant human body electrostatic discharge energy, and enabling the human body to discharge static electricity safely. At the same time, it can detect whether the contact between the human body and the electrostatic touch ball is reliable, and the audible and visual alarm prompts whether the static elimination is complete.
The design of WH-7900D human body electrostatic discharge alarm refers to the following national standards:
GB12158-2006 "General Guidelines for Preventing Static Electricity Accidents"
GB5074-2002 "Code for Design of Petroleum Depots"
Article 14.3.13 stipulates that: as people wear artificial fabric clothes, artificial fabrics are extremely prone to static electricity. They tend to accumulate on the human body. In order to prevent the sparks that may be generated by static electricity, it is necessary to install a device to remove human static electricity on the escalator or the entrance to the oil pump room, the top of the light oil tank, the operating platform in the light oil work area, and the explosion danger area. This anti-static device refers to a handrail made of a metal tube. Before entering these places, the human body should touch the handrail to eliminate static electricity from the human body.
SH3097-2000 "Code for Design of Electrostatic Buildings in Petrochemical Industry"
The human body electrostatic discharge alarm passed the National Explosion-proof Electrical Product Quality Supervision and Inspection Center {NCEX}, and meets the following standards: GB3836.1-2010 Explosive environment Part 1: General requirements for equipment
GB3836.4-2010 Explosive environment Part 4: Equipment protected by intrinsically safe "I"
The product explosion-proof mark is ExiallCT4Gc.
Product installation and use precautions
1. The installation of SG-800D electrostatic discharge alarm must meet the relevant requirements of Article 12.2.5.1 of GB836.15-2010 Explosive Environment Part 15: Electrical Installation in Dangerous Locations (Except Coal Mine)
2. The maximum operating environment temperature is between -40 ℃-+ 60 ℃.
3. Do not change the parts of the product by yourself, and should work with the product manufacturer to resolve the failures during operation to prevent damage.
4. Installation, use and maintenance of the product shall comply with the product manual, GB3836.12-2010 Explosive Environment Part 13: Maintenance of electrical equipment used in explosive gas environment, GB3836.15-2010 Explosive Environment Part 15: Electrical in hazardous areas Installation (except coal mines), GB-3836.16-2010 Explosive environment Part 16: Inspection and maintenance of electrical installations (except coal mines) and GB-50257-1996 "Code for construction and acceptance of electrical installations in explosion and fire hazard environments of electrical installations" Related provisions.
5. When the product does not work properly, you need to change the explosion-proof touch ball.
Equipment maintenance
1. Keep the equipment clean and regularly clean the dust and oil on the explosion-proof touch ball to prevent the sensitivity of the explosion-proof touch ball from decreasing.
2. Regularly inspect and repair the equipment, and check whether the grounding bolts and other accessories of the ground wire are loose to avoid causing poor contact.
* ShunGuan reserves the right to modify the above product performance parameters and technology at any time without notice.

Pole mounting

Ground wire installation The ground wire is connected to the ground stake with NB bolts, and the two copper noses are connected separately (as shown below)

Instructions for use

Product warranty commitment
Our company strictly abides by the tenet of product quality first, reputation first, customer first, and implements the following commitments on all products sold by our factory:
1. Warranty period The warranty period of the products sold by the company is one year. The quality problems caused by the product's own mechanical parts, materials and workmanship within one year from the date of sale will be replaced or repaired by the factory free of charge.
2. Service after the warranty period All products sold by the company after the warranty period are still responsible for repairing the product without labor costs to protect the interests of customers.
3. Our company provides free maintenance, testing and other services for ion fans once a quarter; if some equipment is found to have quality problems during the maintenance process, in order to ensure the normal operation of the user, our company will provide new products to replace the work area, waiting for This product will be delivered to the user after being calibrated; if it cannot be calibrated, our factory will replace the new product for free.
4. Once a technical failure occurs, the factory will solve the problem for the user's phone as soon as possible. If the phone cannot solve the problem, it will overtake the fault site within 12 hours within 300 axioms of the service point; within two hours from 300 kilometers Take the fastest way, provide new equipment within 48 hours and replace the faulty equipment with the production line.

Mode of transportation:
1. Logistics (SF, Debang, Shentong, Suer)
2. Within the Pearl River Delta, deliver more to your door
Arrival time:
1. Within the Pearl River Delta, arrive within 24 hours
2. Provinces, 2-3 working days

payment method:
1. Standard products, customers in the Pearl River Delta, cash on delivery; customers in other provinces, delivery on delivery. Special circumstances can be handled specially.
2. Custom-made products with special models, 50% deposit in advance, and cash on delivery for the rest.
Payment account:
For corporate accounts (customers who issue VAT invoices):
Company Name: Shenzhen Weihan Antistatic Technology Co., Ltd.
Tax ID: 4403 0031 9431 443
Account number: 000176947742
Bank: Gongle Sub-branch, Shenzhen Agricultural Commercial Bank

Phone: 18487903773 Email: szweihan@qq.com
Address: No. 53 Xisan Street, Fuxin District, Qiaotou Community, Houjie Town, Dongguan City, Guangdong ICP No. 15010061 [ Baidu Statistics ]
Copyright © 2003-2014 cnciu.com, All Rights Reserved BMAP GMAP

  • QQ交流
  • QQ交流
  • QQ交流
Wechat QR code
炸金花 炸金花 炸金花 炸金花